Figure 63:
22. Install stationary seat into gland (107) per seal manufacturer's instructions.
23. Slide gland (107) with stationary seat over shaft, up to adapter face (Fig . 61).
WARNING:
Wear a heavy set of work gloves when handling impeller (101) as sharp edges may cause
physical injury.
24. Install impeller (101) with new 0-ring (412A). Put wrench on shaft. When impeller (101) makes firm
contact with sleeve (126), raise shaft wrench (counterclockwise when viewed from impeller end of
shaft) and slam it down {clockwise when viewed from impeller end of shaft). A few sharp raps will
tighten impeller (101) properly (Fig. 63).
Figure 64:
25. Install Impeller anti-rotation device (458Y) making sure the 0-ring (428D) is in good condition. Re-
place if needed (Fig. 64).
NOTICE:
Be sure to use a properly balanced impeller.
6.9 Reassembly
58
3196CC Installation, Operation and Maintenance Instructions