Figure 53:
6.
Install seal chamber cover or backplate (184) with nuts (370H) Fig. 52).
Figure 54:
7.
Check seal chamber cover run-out. Rotate indicator through 360 degrees. If total indicator reading
is greater than 0.005 in. (.13 mm), determine cause and correct before proceeding (Fig. 53).
8.
Install shaft sleeve (126) if used (Fig. 54 & 55).
NOTICE:
Make sure sleeve is fully seated.
WARNING:
Wear a heavy set of work gloves when handling impeller (101) as sharp edges may cause
physical injury.
6.9 Reassembly
3196CC Installation, Operation and Maintenance Instructions
53