6.7.4 Frame adapter
1.
Check frame adapter (108) for cracks or excessive corrosion damage. Replace if any of these
.
2.
Make sure gasket surface is clean.
Figure 49:
6.8 Reassembly
Refer to following table for torque values while reassembling pump.
Table 5: Maximum Torque Values in ft.-lb. (Nm) for Casing Bolts (370)
Models 3196, CV 3196 LF 3196, 3796
with 150 lb. Casing flanges
Model HT 3196 and all Mod-
els
6.8 Reassembly
50