NOTICE:
The face of the CV 3196 impeller is not machined. Checking the face runout on the CV 3196 is
note required.
37. Install packing and gland according to
6.10 All models STX, MTX, LTX, XLT-X, X17
6.11 Reinstall Back Pull-Out Assembly
WARNING:
Back pull-out assembly weighs more than 50 lbs. Do not handle unassisted as physical injury
may occur.
1.
Clean casing fit and install casing gasket (351) in place on seal chamber/stuffing box cover.
2.
Install back pull-out assembly in casing (Fig. 74).
Figure 74:
3.
Install casing bolts (370), finger tight. Casing bolts (370) may be coated with anti-galling compound
to aid disassembly. Tighten the casing bolts per
Table 5: Maximum Torque Values in ft.-lb. (Nm) for
torque values. Install casing jack screws (418), snug tight
.
NOTICE:
Do not overtighten casing jack screws (418).
4.
Replace shims under motor frame foot and tighten frame foot to baseplate. To ensure that the prop-
er shim is used, a dial indicator should be mounted to measure distance between top of frame and
baseplate. This distance should not change as frame foot bolting is tightened.
5.
Replace auxiliary piping at this time.
6.10 All models STX, MTX, LTX, XLT-X, X17
3196CC Installation, Operation and Maintenance Instructions
63