Cushioning devices should be used to protect the pump from surges and water hammer if quick-
closing valves are installed in system.
3.7 Final piping check
After connecting the piping to pump:
1.
Rotate shaft several times by hand to be sure that there is no binding and all parts are free.
2.
Check alignment, per the alignment procedure outlined previously to determine absence of pipe
strain. If pipe strain exists, correct piping.
3.7 Final piping check
24
3196CC Installation, Operation and Maintenance Instructions