Figure 59:
NOTICE:
If installing a cartridge mechanical seal, the shaft or sleeve does not need to be marked. The
seal is self setting.
17. Check impeller (101) runout. Check vane tip to vane tip. If total indicator reading is greater than
0.005 in. (.13 mm), determine cause and correct before proceeding (Fig. 57).
Figure 60:
18. Remove impeller (101), and shaft sleeve (126) if used (Fig. 59).
6.9 Reassembly
56
3196CC Installation, Operation and Maintenance Instructions