Figure 31:
4.
Rotate the impeller clockwise (viewed from the impeller end of the shaft), raising the wrench.
5.
Quickly turn the impeller counterclockwise (viewed from the impeller end of the shaft), impacting
the wrench handle until the impeller loosens (Fig. 30).
6.
Remove impeller 0-ring (412A) and discard. Replace with a new o-ring during reassembly (Fig.
32 and 33).
Figure 32:
6.2 Disassembly
3196CC Installation, Operation and Maintenance Instructions