Model
Casing
Impeller
the casing feet as well as the motor feet for solid
support.
by a PTFE ring. The impeller is the
same as used in the CV 3196 with the
exception it has an anti-rotation option.
The 3196 CC, CV 3196 CC, and 3796 use the
same seal chambers. These are also inter-
changeable with the following other Goulds
Models: 3196, CV 3196, HT 3196, and LF 319.
Frame Adapter - The frame adapters for
the 3196 CC, CV 3196 CC, and 3796
are each machined specifically for the
pump / motor combinations.
2.3 Nameplate information
Every pump has a Goulds nameplate that provides information about the pump. The nameplate is locat-
ed on the casing.
Pump Casing Tag - provides information about the pump's hydraulic characteristics. Note the format of
the pump size: Discharge x Suction - Nominal maximum Impeller Diameter in inches. (Example: 2x3-8)
(Figs. 2 & 3).
Figure 2: English nameplate
Figure 3: Metric nameplate
2.4 Receiving the pump
Inspect the pump as soon as it is received. Carefully check that everything is in good order. Make notes
of damaged or missing items on the receipt and freight bill. File any claims with the transportation com-
pany as soon as possible.
2.3 Nameplate information
3196CC Installation, Operation and Maintenance Instructions
11