2 General Information
2.1 Pump description
Model
Pump Description
Size Groups
No. of Sizes
3196 CC
This model has five (5) hydraulic pump sizes.
It has a casing which is ANSI B73 dimensionally compliant and open im-
peller design.
MTX
5
CV 3196 CC
This model has two (2) pump sizes.
It is a horizontal overhung, recessed impeller, centrifugal pump specifical-
ly designed to handle bulky or fibrous solids, air, gas or shear sensitive
liquids.
MTX
2
3796
This model has three (3) hydraulic pump sizes.
The 3796 is a horizontal overhung, self priming, open impeller, centrifugal
pump.
MTX
3
2.2 ANSI Family Parts Commonality
All of Goulds Pumps horizontal ANSI pumps share the same stuffing box covers and seal chambers. The
non-metallic units all have unique casings, impellers, and seal chambers. The chart on the following pa-
ges demonstrates the parts commonality and the relationship between the model lines.
Model
Casing
Impeller
3196 CC
The casing is top centerline discharge and self-
venting. The gasket is fully confined. ANSI class
150 flanges are standard. The pump is mounted
on the casing feet as well as the motor for solid
support. Flange-to-flange dimensions meet ANSI
B73.
The impeller is fully open and threaded
to the shaft. Threads are sealed from
the pumpage by an 0-ring (PTFE). The
impeller is the same as used in the con-
ventional Models 3196 and 3796 with
the exception it has an anti-rotation op-
tion.
3796 CC
The casing is top centerline discharge and self-
venting. It has an integrally cast priming cham-
ber that allows the pump to evacuate air to prime
itself. The gasket is fully confined. An integral
foot support is used for maximum resistance to
misalignment and distortion from piping loads.
ANSI class 150 raised face serrated flanges are
available as an option. The casing comes with a
provision to accept an immersion heater to keep
the liquid in the priming chamber from freezing in
outdoor applications.
CV 3196 CC
The casing is tangential discharge and has a
fully confined gasket. ANSI flat faced 150 #
flanges are standard. The pump is mounted on
The impeller is fully open and recessed
from the casing. It has curved vanes
and is threaded to the shaft. The
threads are sealed from the pumpage
2 General Information
10
3196CC Installation, Operation and Maintenance Instructions