1. GENERAL INFORMATION

Before using the product carefully read the information contained 

in this instruction manual, the manual should be kept for future 

reference.

This manual is part of the essential safety requirement and must 

be retained until the product is finally decommissioned.

The customer, in case of loss, can request a copy of the manual 

by contacting the manufacturer or their agent, specifying the 

type of product data shown on the label of the machine (see 2.3 

Marking)

Any changes, alterations or modifications made to the product or 

part of it, not authorized by the manufacturer, will revoke the “CE 

declaration” and warranty.

This appliance should not be operated by children younger 

than 8 years, people with reduced physical, sensory or mental  

capacities, or inexperienced people who are not familiar with the 

product, unless they are given close supervision or instructions 

on how to use it safely and are made aware by a responsible 

person of the dangers its use might entail.

Children must not play with the appliance.

It is the user’s responsibility to clean and maintain the appliance. 

Children should never clean or maintain it unless they are given 

supervision.

Do not use in ponds, tanks or swimming pools or where people 

may enter or come into contact with the water.

Read carefully the installation section which sets forth:

- The maximum permissible structural working pressure 

 

(chapter 3.1).

- The type and section of the power cable (chapter 6.5).

- The type of electrical protection to be installed (chapter 6.5).

1.1. Symbols

To improve the understanding of the manual, below are

indicated the symbols used with the related meaning.

Information and warnings that must be observed, 

otherwise there is a risk that compromise personnel 

safety.

The failure to observe electrical information and 

 

warnings, could damage the machine or compromise 

personnel safety.

Information and warnings that must be observed, 

otherwise there is a risk that compromise personnel 

safety.

Notes and warnings for the correct management of the 

machine and its parts.

Operations that could be performed by the final 

user. After carefully reading of the instructions, is  

responsible for maintenance under normal conditions. 

They are authorized to affect standard maintenance 

operations.

SHALLOW WELL PUMPS

JCC - JSC

INSTALLATION AND OPERATING INSTRUCTIONS

Operations that must be performed by a qualified elec-

trician. Specialized technician authorized to affect all 

electrical operations including maintenance. They are 

able to operate with in the presence of high voltages.

Operations that must be done performed by a 

 

qualified technician. Specialized technician able 

to install the device, under normal conditions, 

 

working during “maintenance”, and allowed to 

do electrical and mechanical interventions for 

 

maintenance. They must be capable of executing simple  

electrical and mechanical operations related to the 

maintenance of the device.

Indicates that it is mandatory to use individual 

 

protection devices.

OFF - Operations that must be done with the device 

switched off and disconnected from the power supply.

ON - Operations that must be done with the device

switched on.

1.2. Authorized operators

The product is intended for use by expert operators divided into 

end users and specialized technicians. (see the symbols above).

It’s forbidden, for the end user, carry out operations which must 

be done only by specialized technicians. The manufacturer  

declines any liability for damage related to the non-compliance 

of this warning.

1.3. Warranty

For the product warranty refer to the general terms and 

 

conditions of sale.

i

OFF

ON

i

OFF

ON

i

OFF

ON

i

OFF

ON

i

OFF

ON

i

OFF

ON

i

OFF

ON

i

OFF

ON

i

OFF

ON

i

OFF

ON

Содержание JCC Series

Страница 1: ...hat compromise personnel safety The failure to observe electrical information and warnings could damage the machine or compromise personnel safety Information and warnings that must be observed otherwise there is a risk that compromise personnel safety Notes and warnings for the correct management of the machine and its parts Operations that could be performed by the final user After carefully rea...

Страница 2: ...well ventilated location protected from the weather with a maximum ambient temperature of 104 F 4 SAFETY 4 1 General provisions Before using the product it is necessary to know all the safety indications Carefully read all operating instructions and the indications defined for the different steps from transportation to disposal The specialized technicians must carefully comply with all a pplicable...

Страница 3: ...ansmit stress strain or vibrations to the pump par 13 fig 3 Tighten the pipes or union coupling to the extent sufficient to ensure a tight seal Excessive torque may cause damage to the pump When the pipe or union coupling is mounted keep the pump casing connection blocked with a second wrench making sure the connection is not deformed by excessive tightening The pipe diameters must not be smaller ...

Страница 4: ...eded Otherwise adjust the delivery gate valve or the setting of any pressure switches If a priming loss occurs interruption of delivery flow or if a pressure oscillation is indicated by the pressure gauge make sure all the suction pipe couplings are perfectly sealed and tighten the two sealed plugs on the pump casing Never run the pump for more than five minutes with a closed gate valve Prolonged ...

Страница 5: ...fore dismantling the pump 8 3 Dismantling the pump Close the suction and delivery gate valves and drain the pump casing before dismantling the pump par 13 fig 5 For dismantling and re assembly see construction in the cross section drawing 9 DISPOSAL The final disposal of the device must be done by specialized company Make sure the specialized company follows the classification of the material part...

Страница 6: ...ce of deposits or solid bodies in the internal passages of the rotor Clean the rotor and install a suction filter to prevent other foreign bodies from entering 4c Rotor deteriorated Replace the rotor if necessary contact an authorised service centre 4d Worn rotor and pump case Replace the rotor and the pump casing 4e Excessive viscosity of the liquid pumped if other than water The pump is unsuitab...