Figure 33:
NOTICE:
It is recommended that the motor foot be clamped to the workbench when using this method to
remove the impeller.
6.3 Removal of seal chamber cover (mechanical seal)
1.
Remove gland stud nuts (355).
2.
Remove seal chamber stud nuts (370H).
3.
Remove seal chamber (184) (Fig.34).
Figure 34:
4.
Remove shaft sleeve (126), if used.
NOTICE:
Mechanical seal is attached to sleeve (126). Rotary portion of seal needs to be removed from
sleeve by loosening set screws and sliding it off the sleeve. Refer to mechanical seal instruc-
tions.
5.
Remove gland (250) with stationary seat and 0-ring (360Q).
6.3 Removal of seal chamber cover (mechanical seal)
42
3196CC Installation, Operation and Maintenance Instructions