4
Maintenance and adjustment
85
Caution
The amount of track rod screwed
into each ball joint must be equal on
both sides of the tractor.
* The bolts securing the track rod to
the steering ram must be in the
horizontal position.
Electrical equipment (Figs. 57
to 72)
To avoid damage to the components of
the alternator charging system, the follow-
ing service precautions must be observed:
*
NEVER make or break any of the charging
circuit connections, including the bat-
tery when the engine is running.
*
NEVER short any of the charging compo-
nents to earth.
*
ALWAYS disconnect the battery earth
cable before carrying out arc welding on
the tractor.
*
ALWAYS disconnect the battery earth
cable when charging the battery in the
tractor.
*
DO NOT use a slave battery of higher
than 12 volt nominal voltage.
*
ALWAYS observe correct polarity when
installing the battery or using a slave
battery to start the engine.
*
ALWAYS connect the negative cable first.
Positive terminal and cable
(red)
Negative terminal and cable marked -
(black)
The electrical circuit is a 12 volt nega-
tive earth system and requires little atten-
tion. Check and ensure that all cables are
secured in place and that terminals are
tight.
Fuse replacement (Figs. 57 and 58)
The main fuse box (1) is situated be-
hind the left hand instrument panel side
cover (Fig. 57).
Fig. 57:
Fig. 58:
Содержание ITM 475
Страница 1: ...Iran Tractor Industrial Group OPERATOR INSTRUCTION BOOK Tractor Models ITM 475 2WD 4WD ITM 485 2WD 4WD...
Страница 3: ......
Страница 5: ......
Страница 23: ...General information 1 16 Safety decal location Both side Both side Both side...
Страница 24: ...1 General information 17 General decal location...
Страница 25: ......
Страница 37: ......
Страница 116: ...5 Specifications 109 Wiring diagram ITM 475 ITM 485...
Страница 117: ......