Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P01.02
Retention
time of
starting
frequency
0.0~50.0s
0.0s
◎
P01.03
The braking
current
before
starting
0.0~100.0%
0.0%
◎
P01.04
The braking
time before
starting
0.00~50.00s
0.00s
◎
P01.05
ACC/DEC
selection
0:Linear type
0
◎
P01.08 Stop mode
0: Decelerate to stop
1: Coast to stop
0
○
P01.09
Starting
frequency
of DC
braking
0.00Hz~P00.03 (Max. output frequency)
0.00Hz
○
P01.10
Waiting
time of DC
braking
0.00~50.00s
0.00s
○
P01.11
DC braking
current
0.0~100.0%
0.0%
○
P01.12
DC braking
time
0.00~50.00s
0.00s
○
P01.13
Dead time
of
FWD/REV
rotation
0.0~3600.0s
0.0s
○
P01.14
Shifting
0:Switch after zero frequency
1
◎