Intel® Server System M20MYP1UR System Integration and Service Guide
88
Error Code
Error Message
Action message
Response
857C
CPU2_DIMM_B2 encountered a Serial Presence
Detection (SPD) failure
Major
857D
CPU2_DIMM_B3 encountered a Serial Presence
Detection (SPD) failure
Major
857E
CPU2_DIMM_C1 encountered a Serial Presence
Detection (SPD) failure
Major
857F
(Go to 85E0)
CPU2_DIMM_C2 encountered a Serial Presence
Detection (SPD) failure
Major
85C0
CPU2_DIMM_C3 failed test/initialization
Please remove the disabled DIMM.
Major
85C1
CPU2_DIMM_D1 failed test/initialization
Please remove the disabled DIMM.
Major
85C2
CPU2_DIMM_D2 failed test/initialization
Please remove the disabled DIMM.
Major
85C3
CPU2_DIMM_D3 failed test/initialization
Please remove the disabled DIMM.
Major
85C4
CPU2_DIMM_E1 failed test/initialization
Please remove the disabled DIMM.
Major
85C5
CPU2_DIMM_E2 failed test/initialization
Please remove the disabled DIMM.
Major
85C6
CPU2_DIMM_E3failed test/initialization
Please remove the disabled DIMM.
Major
85C7
CPU2_DIMM_F1 failed test/initialization
Please remove the disabled DIMM.
Major
85C8
CPU2_DIMM_F2 failed test/initialization
Please remove the disabled DIMM.
Major
85C9
CPU2_DIMM_F3 failed test/initialization
Please remove the disabled DIMM.
Major
85CA
CPU2_DIMM_G1 failed test/initialization
Please remove the disabled DIMM.
Major
85CB
CPU2_DIMM_G2 failed test/initialization
Please remove the disabled DIMM.
Major
85CC
CPU2_DIMM_G3 failed test/initialization
Please remove the disabled DIMM.
Major
85CD
CPU2_DIMM_H1 failed test/initialization
Please remove the disabled DIMM.
Major
85CE
CPU2_DIMM_H2 failed test/initialization
Please remove the disabled DIMM.
Major
85CF
CPU2_DIMM_H3 failed test/initialization
Please remove the disabled DIMM.
Major
85D0
CPU2_DIMM_C3 disabled
Please remove the disabled DIMM.
Major
85D1
CPU2_DIMM_D1 disabled
Please remove the disabled DIMM.
Major
85D2
CPU2_DIMM_D2 disabled
Please remove the disabled DIMM.
Major
85D3
CPU2_DIMM_D3 disabled
Please remove the disabled DIMM.
Major
85D4
CPU2_DIMM_E1 disabled
Please remove the disabled DIMM.
Major
85D5
CPU2_DIMM_E2 disabled
Please remove the disabled DIMM.
Major
85D6
CPU2_DIMM_E3 disabled
Please remove the disabled DIMM.
Major
85D7
CPU2_DIMM_F1 disabled
Please remove the disabled DIMM.
Major
85D8
CPU2_DIMM_F2 disabled
Please remove the disabled DIMM.
Major
85D9
CPU2_DIMM_F3 disabled
Please remove the disabled DIMM.
Major
85DA
CPU2_DIMM_G1 disabled
Please remove the disabled DIMM.
Major
85DB
CPU2_DIMM_G2 disabled
Please remove the disabled DIMM.
Major
85DC
CPU2_DIMM_G3 disabled
Please remove the disabled DIMM.
Major
85DD
CPU2_DIMM_H1 disabled
Please remove the disabled DIMM.
Major
85DE
CPU2_DIMM_H2 disabled
Please remove the disabled DIMM.
Major
Содержание M20MYP1UR
Страница 2: ...Intel Server System M20MYP1UR System Integration and Service Guide 2 Blank page...
Страница 56: ...Intel Server System M20MYP1UR System Integration and Service Guide 56 Figure 54 DIMM fault LEDs...
Страница 103: ...Intel Server System M20MYP1UR System Integration and Service Guide 103 1 2 3 4 5 ESD 6 1 2 3...
Страница 104: ...Intel Server System M20MYP1UR System Integration and Service Guide 104 1 2 3 4 5...