Intel® Server System M20MYP1UR System Integration and Service Guide
29
2.5
Drive Carrier Extraction, Installation, and Assembly
The server system includes four
front drive bays that support 3.5”
hard disk drives or SDDs with the option
to support 2.5” SSDs.
This section provides instructions for drive extraction from the chassis, drive
installation into the chassis, and drive assembly.
Note:
To maintain proper system cooling, the drive bays must be populated with a drive carrier. Each drive
carrier must have installed a hard disk drive (HDD), Solid State Device (SSD), or a supplied drive blank.
Required Tools and Supplies:
•
Anti-static wrist strap and conductive workbench pad (recommended)
2.5.1
Drive Carrier Extraction
Figure 25. Extracting drive carrier from chassis
1.
Remove the drive carrier from the chassis by first pressing the button on the carrier face plate to release
the lever (see Letter A).
2.
Using the lever, release the latch of the drive carrier.
3.
Pull the carrier from the drive bay (see Letter B).
2.5.2
Drive Carrier Installation
Figure 26. Installing drive carrier into chassis
1.
Align the drive assembly with the open drive bay.
2.
With the lever in the open position, insert the drive assembly into the drive bay (see letter A) and push
forward until the drive makes contact with the backplane.
3.
Complete the drive installation by closing the drive assembly lever until it locks into place (see letter B).
Содержание M20MYP1UR
Страница 2: ...Intel Server System M20MYP1UR System Integration and Service Guide 2 Blank page...
Страница 56: ...Intel Server System M20MYP1UR System Integration and Service Guide 56 Figure 54 DIMM fault LEDs...
Страница 103: ...Intel Server System M20MYP1UR System Integration and Service Guide 103 1 2 3 4 5 ESD 6 1 2 3...
Страница 104: ...Intel Server System M20MYP1UR System Integration and Service Guide 104 1 2 3 4 5...