Intel® Server System M20MYP1UR System Integration and Service Guide
36
3.2
PCIe* Add-in Card Removal / Installation
The server system supports up to two PCIe* add-in cards via two included riser card assemblies. This section
provides instructions for the removal and installation of the riser card assemblies, as well as the installation
and removal of an add-in card to/from the riser assembly.
Required Tools and Supplies:
•
Anti-static wrist strap and conductive workbench pad (recommended)
•
Phillips* (cross head) screwdriver (#2 bit)
3.2.1
Riser Card Bracket Removal
1.
Power off the system and disconnect the AC power cord.
2.
Remove the system top cover (see Section 2.1.1).
3.
Remove the air duct (see Section 2.2.1).
Figure 35. PCIe* riser card bracket removal
4.
Grasp the riser card bracket with both hands and carefully lift it up to remove it from the system making
sure the three mounting tabs in the back of the riser card bracket disengage from the chassis.