Intel® Server System M20MYP1UR System Integration and Service Guide
26
Figure 20. Releasing processor from carrier clip
8.
Remove the processor from the processor clip by carefully pushing back one of the latches located on
the ends of the processor and rotating the processor up and out of the processor carrier clip.
9.
For PHM assembly and installation see Section 2.3.2
2.4
Memory Module (DIMM) Installation and Replacement
Required Tools and Supplies:
•
Anti-static wrist strap and conductive workbench pad (recommended)
General Memory Population Rules:
Note:
For details on DIMM population rules, refer to the
Intel® Server System M20MYP1UR Technical Product
Specification
.
•
Each installed processor provides six memory channels. On the Intel® Server System M20MYP1UR,
memory channels for each processor are labeled A
–
F. Channels A and D on each processor support
two DIMM slots. All other memory channels have one DIMM slot.
•
Channels that support more than one DIMM must be populated starting with the BLUE DIMM slot. In
addition, when installing a Quad-rank DIMM with a Single- or Dual-rank DIMM in the same channel,
the Quad-rank DIMM slot farthest from the processor must be populated.
To maintain required airflow within the system, certain memory slots
MUST
be populated with a DIMM or
supplied DIMM blank. DIMM blanks should only be removed when installing a DIMM into the same memory
slot.
Figure 21. DIMM blank
Содержание M20MYP1UR
Страница 2: ...Intel Server System M20MYP1UR System Integration and Service Guide 2 Blank page...
Страница 56: ...Intel Server System M20MYP1UR System Integration and Service Guide 56 Figure 54 DIMM fault LEDs...
Страница 103: ...Intel Server System M20MYP1UR System Integration and Service Guide 103 1 2 3 4 5 ESD 6 1 2 3...
Страница 104: ...Intel Server System M20MYP1UR System Integration and Service Guide 104 1 2 3 4 5...