Intel® Server System M20MYP1UR System Integration and Service Guide
30
2.5.3
3.5” HDD/SSD Drive Assembly
Figure 27. 3.5" Drive carrier assembly - drive / drive blank removal
1.
Remove the drive or drive blank from the carrier by holding the carrier assembly top side down in your
right hand. Using your left hand, gently rotate the bottom edge of the left rail upwards (see Letter A)
while at the same time pushing the drive or drive blank down away from the carrier (see Letter B).
Figure 28
. 3.5” Drive
carrier assembly
–
drive installation to carrier
2.
With the rear drive connector positioned towards the back of the drive carrier, align and position the
screw holes on the left side of the drive over the mounting tabs located on the drive carrier side rail (see
letter E).
3.
Lower the other side of the drive into the carrier and press down until all mounting tabs lock in place.
Содержание M20MYP1UR
Страница 2: ...Intel Server System M20MYP1UR System Integration and Service Guide 2 Blank page...
Страница 56: ...Intel Server System M20MYP1UR System Integration and Service Guide 56 Figure 54 DIMM fault LEDs...
Страница 103: ...Intel Server System M20MYP1UR System Integration and Service Guide 103 1 2 3 4 5 ESD 6 1 2 3...
Страница 104: ...Intel Server System M20MYP1UR System Integration and Service Guide 104 1 2 3 4 5...