Intel® Server System M20MYP1UR System Integration and Service Guide
63
7.2
Replacing a System Fan
Required Tools and Supplies:
•
Anti-static wrist strap and conductive workbench pad (recommended)
System fans used in the Intel Server System M20MYP1UR product are NOT hot-swappable.
Warning
: System fans operate at extremely high speeds. Do not attempt to replace a system fan until it has
stopped completely. Attempting to remove a fan that is not completely stopped may result in injury.
Figure 58. System fan assembly removal
1.
Power off the system and remove the system top cover (see Section 2.1.1).
2.
Remove the air duct (see Section 2.3.1)
3.
Disconnect the cable of the target fan from the server board (see Letter A).
Note:
Disconnecting the cables from the remaining fans is not required.
4.
Lift the system fan up and away from the chassis (see Letter B).
Содержание M20MYP1UR
Страница 2: ...Intel Server System M20MYP1UR System Integration and Service Guide 2 Blank page...
Страница 56: ...Intel Server System M20MYP1UR System Integration and Service Guide 56 Figure 54 DIMM fault LEDs...
Страница 103: ...Intel Server System M20MYP1UR System Integration and Service Guide 103 1 2 3 4 5 ESD 6 1 2 3...
Страница 104: ...Intel Server System M20MYP1UR System Integration and Service Guide 104 1 2 3 4 5...