Intel® Server System M20MYP1UR System Integration and Service Guide
42
3.6
M.2 SSD Installation / Removal
Required Tools and Supplies:
•
Anti-static wrist strap and conductive workbench pad (recommended)
•
Phillips* (cross head) screwdriver (#2 bit)
The system supports up to two PCIe*/SATA 2280 (80 mm) M.2 SSD devices in a stacked configuration
secured by a bracket. The following illustration shows the location for both the connectors and the bracket.
Figure 43. M.2 connector and bracket identification
3.6.1
Installing One M.2 Device (Single Configuration)
Figure 44.
Installing one M.2 SSD device
1.
Power off the system and disconnect the AC power cord.
2.
Remove the system top cover (see Section 2.1.1).
3.
Locate the top M.2 connector on the server board near the DIMM slots.
4.
Remove the bracket using a Phillips* (cross head) screwdriver.
5.
Attach the bracket to the M.2 device with the provided screw (see letter A).
6.
Slide the M.2 device into the connector (see Letter B).
7.
Secure the M.2 bracket to the server board with the provided screw (see Letter C).
Содержание M20MYP1UR
Страница 2: ...Intel Server System M20MYP1UR System Integration and Service Guide 2 Blank page...
Страница 56: ...Intel Server System M20MYP1UR System Integration and Service Guide 56 Figure 54 DIMM fault LEDs...
Страница 103: ...Intel Server System M20MYP1UR System Integration and Service Guide 103 1 2 3 4 5 ESD 6 1 2 3...