Intel® Server System M20MYP1UR System Integration and Service Guide
91
Table 9. Integrated BMC beep codes
Code
Reason for Beep
Associated Sensors
1-5-1-2
VR Watchdog Timer sensor assertion
VR Watchdog Timer
1-5-1-4
The system does not power on or
unexpectedly power off and a power
supply unit (PSU) is present that is an
incompatible model with one or more
other PSUs in the system
PS Status
1-5-2-1
No CPUs installed or first CPU socket is
empty
CPU Missing Sensor
1-5-2-2
CPU CAT Error (IERR) assertion
CPU ERR2 Timeout Sensor
1-5-2-3
CPU ERR2 timeout assertion
CPU ERR2 Timeout Sensor
1-5-2-4
CPU Icc max Mismatch
CPU Icc max Mismatch Sensor
1-5-2-5
CPU population error
CPU 0 Status Sensor
1-5-4-2
Power fault: DC power is unexpectedly
lost (power good dropout).
Power unit
–
power unit failure offset
1-5-4-4
Power control fault (power good
assertion timeout).
Power unit
–
soft power control failure offset