Intel® Server System M20MYP1UR System Integration and Service Guide
57
6.2
System Configuration and Recovery Jumpers
Figure 55. System configuration and recovery jumpers
The following sections describe how each jumper block is used.
6.2.1
BIOS Default Jumper Block
This jumper resets BIOS options, configured using the <F2> BIOS Setup Utility, back to their original default
factory settings.
Note:
This jumper does not reset Administrator or User passwords. To reset passwords, the Password Clear
jumper must be used.
1.
Power down the server and disconnect the AC power cord.
2.
Remove the system top cover
3.
Move the
“BIOS DFLT” jumper
from pins 1-2 (default) to pins 2-3 (Set BIOS Defaults).
4.
Wait 5 seconds then move the jumper back to pins 1-2.
5.
Re-install the system top cover.
6.
Re-Install system power cord
Note:
The system automatically powers on after AC is applied to the system.
7.
During POST, access the <F2> BIOS Setup utility to configure and save desired BIOS options