Intel® Server System M20MYP1UR System Integration and Service Guide
28
2.4.1
DDR4 DIMM Installation
Figure 23. DDR4 DIMM installation
1.
Locate the DIMM slots. Make sure the clips at either end of the DIMM slot(s) are pushed outward to the
open position (see Letter A).
2.
Holding the DIMM by the edges, remove it from its anti-static package. Position the DIMM above the slot.
Align the notch on the bottom edge of the DIMM with the key in the DIMM slot (see Letter B).
3.
Insert the bottom edge of the DIMM into the slot (see Letter C).
4.
When the DIMM is inserted, push down on the top edge of the DIMM until the retaining clips snap into
place (see Letter D).
5.
Make sure the clips are firmly in place (see Letter E).
2.4.2
DDR4 DIMM Replacement
Figure 24. DDR4 DIMM Removal
1.
Locate the DIMM slot for service. Ensure that the retaining clips of adjacent slots are closed.
2.
Open the DIMM slot latches at either end of the selected DIMM slot (see Letter A). The DIMM will lift up
from the slot connectors.
3.
Holding the DIMM by its edges, lift it away from the slot (see Letter B).
For DIMM installation, see Section 2.4.1.