-404-
11 Appendix
Parameter Group
Name
Option Description
Value Range Default
Min.
unit
Width
Setting
Condition
Effective
Time
Hexadecimal Decimal
Group
Index
Code
Para.
No.
200E
1Bh
H0E-26
Maximum value
of invalid frames
and errors of
EtherCAT port 1
per unit time
-
0–0xFFFF
0
1
16 bits
-
-
1Ch H0E-27
Maximum value
of transfer errors
of EtherCAT port
per unit time
-
0–0xFFFF
0
1
16 bits
-
-
1Dh H0E-28
Maximum value
of EtherCAT data
frame processing
unit errors per unit
time
-
0–0x0255
0
1
16 bits
-
-
1Eh H0E-29
Maximum value
of link loss of
EtherCAT port 0
per unit time
-
0–0xFFFF
0
1
16 bits
-
-
20h H0E-31
EtherCAT
synchronization
mode setting
-
0–2
1
1
16 bits At stop
Next
power-on
21h H0E-32
EtherCAT
synchronization
error threshold
-
100–4000
3000
1 μs
16 bits At stop Immedi-
ately
22h H0E-33
Connection state
between EtherCAT
state machine and
the port
-
0–65535
0
1
16 bits
-
-
23h H0E-34
Excessive CSP
position reference
increment count
-
0–7
1
1
16 bits During
running
Immedi-
ately
25h H0E-36
EtherCAT AL
enhanced link
selection
0: Disable
1: Enable
0–1
0
1
16 bits During
running
Next
power-on
26h H0E-37 EtherCAT reset
XML selection
0: Disable
1: Enable
0–1
0
1
16 bits During
running
Next
power-on
51h H0E-80 Modbus baud rate
0: 300 bps
1: 600 bps
2: 1200 bps
3: 2400 bps
4: 4800 bps
5: 9600 bps
6: 19200 bps
7: 38400 bps
8: 57600 bps
9: 115200 bps
0–9
9
1
16 bits During
running
Immedi-
ately
52h H0E-81 Modbus data
format
0: No parity, 2 stop bits
(8-N-2)
1: Even parity, 1 stop
bit (8-E-1)
2: Odd parity, 1 stop bit
(8-O-1)
3: No parity, 1 stop bit
(8-N-1)
0–3
3
1
16 bits During
running
Immedi-
ately
53h H0E-82 Modbus response
delay
-
0–20
0
1 ms
16 bits During
running
Immedi-
ately
Содержание SV660
Страница 178: ...177 6 Gain Tuning Figure 6 18 Example of the waveform...
Страница 359: ...358 10 Application Cases c Click OK d Click Yes...
Страница 360: ...359 10 Application Cases e Click OK f Click No...
Страница 362: ...361 10 Application Cases...
Страница 366: ...365 10 Application Cases 7 2 Controlling the servo operations through the PLC a Create a PLC program...
Страница 370: ...369 10 Application Cases b Add parameters to be monitored to monitor these parameters during PLC running...