-101-
4 Keypad Display and Operations
Code
Name
Function
Description
Remarks
38
TouchProbe1
Touch probe 1
Invalid - Probe not triggered
Valid - Probe can be triggered
The probe logic is only related
to the probe function (60B8h)
instead of the terminal logic.
39
TouchProbe2
Touch probe 2
Invalid - Probe not triggered
Valid - Probe can be triggered
The probe logic is only related
to the probe function (60B8h)
instead of the terminal logic.
Output signal function description
01
S-RDY
Servo ready
Valid - Servo ready
Invalid - Servo not ready
The servo drive is ready to run.
02
TGON
Motor rotating
Invalid - Absolute value of the
filtered motor speed smaller
than the value of H06-16.
Valid - Absolute value of the
filtered motor speed reaching
the value of H06-16.
-
09
BRK
Brake output
Valid: Brake signal outputted
Invalid: Brake signal not
outputted
-
10
WARN
Warning
Valid - Warning occurs on the
servo drive
Invalid - No warning occurs on
the servo drive or the warning
has been reset
-
11
ALM
Fault
Valid - Fault occurs on the servo
drive
Invalid - No fault occurs on the
servo drive or the fault has been
reset
-
25
CMP
Position
comparison
Valid: Servo drive passing the
target position comparison
point
Invalid: Servo drive not passing
the target position comparison
point
-
32
EDM
Safety status
Valid: STO function triggered
Invalid: STO function not
triggered
The EDM will output valid
signals only when the 24 V input
voltages for STO1 and STO2 are
disconnected simutaneously.
1 Forced DI signal
When this function is enabled, all DI levels will be controlled by H0D-18 (Forced DI value).
Содержание SV660
Страница 178: ...177 6 Gain Tuning Figure 6 18 Example of the waveform...
Страница 359: ...358 10 Application Cases c Click OK d Click Yes...
Страница 360: ...359 10 Application Cases e Click OK f Click No...
Страница 362: ...361 10 Application Cases...
Страница 366: ...365 10 Application Cases 7 2 Controlling the servo operations through the PLC a Create a PLC program...
Страница 370: ...369 10 Application Cases b Add parameters to be monitored to monitor these parameters during PLC running...