-277-
7 Control Mode
Position
Position comparison value 2
Position comparison output
Time
Position comparison value 1
Actual position
Pulse output width
■
Only one pulse will be output when the stop position is the same with the position comparison
value, as shown in the following figure.
Actual position
Position
Position comparison
value
Position comparison
output
Time
Pulse output width
3)
Interface of the software tool
For the convenience of setting the target position comparison value, the software tool provides the
function of division setting. Set a proper comparison mode, start point, and end point first.
■
In the single comparison mode, set the total running distance and number of comparison points.
After clicking " 等分设定 " (Division setting), the target value of the first point is updated to “Distance
x 1/Number of comparison points”, the target value of the second point is updated to “Distance x 2/
Number of comparison points”, and the target value of the Nth point is updated to “Distance x N/
Number of comparison points”.
■
In the cyclic comparison mode, " 距离长度 " (Distance length)
is used to set the operating distance
between two adjacent point. "
比较点数 " (Comparison points)
is used to set the numbers of points
to be compared cyclically. After clicking " 等分设定 " (Division setting), the target values of the 1st to
the Nth comparison points are updated to the values set in "
距离长度 " (Distance length).
Содержание SV660
Страница 178: ...177 6 Gain Tuning Figure 6 18 Example of the waveform...
Страница 359: ...358 10 Application Cases c Click OK d Click Yes...
Страница 360: ...359 10 Application Cases e Click OK f Click No...
Страница 362: ...361 10 Application Cases...
Страница 366: ...365 10 Application Cases 7 2 Controlling the servo operations through the PLC a Create a PLC program...
Страница 370: ...369 10 Application Cases b Add parameters to be monitored to monitor these parameters during PLC running...