284
SNMP Configuration
There are three ways in which the primary window of the MibBrowser can be viewed. It can be
viewed with the result display, MIB description panel or multi-variable bind panel in the right
frame. The view can be altered by three ways.
•
The desired view can be set by the options provided in the display menu item under the
view menu. (View
Æ
Display
Æ
).
•
The other way of altering the view is through the general settings panel in the settings menu
item in the edit menu. (Edit
Æ
Settings)
•
The same can be done through clicking the MibBrowser settings button on the toolbar. See
Figure 28-2 below.
Figure 28-2: AdventNet MibBrowser Settings Button on the Toolbar
By default the MIB description display and the result display are visible in the MibBrowser.
28.11.2 Using the TrapViewer
TrapViewer is a graphical tool to view the traps received from one or more SNMP agents running on
a SmartNode 1000 or 2000 series device. The TrapViewer can listen to one or more port at a time and
the traps can be sent from any host. SmartNode 1000 or 2000 series device send their traps to the
SNMP standard port 162.
Invoke the TrapViewer through the usage of the MibBrowser. To get to know more about the
MibBrowser refer to Chapter 28.11.1, “Using the MibBrowser” above. In Figure 28-3 depicted below
is a screen shot of the TrapViewer.
Figure 28-3: AdventNet TrapViewer displaying received Traps
Software Configuration Guide, Revision 1.03