CMN-91
Installation and Operation Manual
Operation
© 2016 Imagine Communications Corp. Proprietary and Confidential.
Revision D | Page 87
Figure 48:
Six Bar Graph Display Diagram
Six Bar Graph Display Diagram
Field
Identifier
Field Information
Nomenclature
1
Input
Displays selected input (A or B)
2
Status
Displays audio type as Mute, AES, or Embedded
Displays audio clip or mute alarm indicators
3
Phase Bar (2)
Phase Meter of bar graph 2
4
Channel Number
Shown as 1-16 (AES is 1-2 and Embedded is 1-16)
5
Device
Displays labels for lissajous, bar graphs, and headphone outputs
6
Phase Bar (3)
Phase Meter of bar graph 3
7
Level Markers
Shows peak and reference levels for the signal; this can be adjusted
in the Audio Meter Setup selection options
8
Zoom
Zoom (when enabled); blank when disabled
9
Scale Selection
Displays the selected meter scale: Type I, Type IIa, Type IIb, Type I +
8, Nordic, DIN 45406, dBFS, Zero REF dBFS, Custom dB, and Custom
dBFS