CMN-91
Installation and Operation Manual
Alarm Descriptions
© 2016 Imagine Communications Corp. Proprietary and Confidential.
Revision D | Page 133
Selection
Selection Option
Selection Option
Selection Option
Loss of Carrier
Enable
Duration
0 to 60 seconds (2
seconds*)
Loss of Reference
Enable
Duration
0 to 60 seconds (2
seconds*)
Loss of Active Video
Enable
Threshold
0 to 350 mV (300 mV*)
Sensitivity
2* to 20 CES
Duration
0 to 60 seconds (2
seconds*)
Loss of Payload Identifier Enable
Duration
0 to 60 seconds (2
seconds*)
Gamut
RGB Gamut Upper
Enable
Threshold
650 to 750 mV (710 mV*)
Sensitivity
1 to 20 CES (15 CES*)
Duration
0 to 60 seconds (2
seconds*)
RGB Gamut Lower
Enable
Threshold
-50 to 50 mV (-10 mV*)
Sensitivity
1 to 20 CES (15 CES*)
Duration
0 to 60 seconds (2
seconds*)
Luminance Gamut Upper Enable
Threshold 525/59.94
90 to 108 IRE (105 IRE*)
Threshold 625/50
92 to 109 Units setting
(107 Units*)
Sensitivity
1 to 20 CES (15 CES*)
Duration
0 to 60 seconds (2
seconds*)
Luminance Gamut Lower Enable
Threshold 525/59.94
1.5* to 20 IRE
Threshold 625/50
-7 to 20 Units setting (-4
Units*)