Field
Identifier
Field Information
Nomenclature
2
Status
Displays audio type as Mute, AES, or Embedded
Displays audio clip or mute alarm indicators
3
Channel Number
Shown as 1-16 (AES is 1-2 and Embedded is 1-16)
4
Device
Displays labels for lissajous, bar graphs, and headphone outputs
5
Lissajous Display (2)
Lissajous of bar graph 2 with labels for R, L, and the number of the
meter being monitored (for example, M-2)
6
Lissajous Display (1)
Lissajous of bar graph 1 with labels for R, L, and the number of the
meter being monitored (for example, M-1)
7
Zoom
Zoom (when enabled); blank when disabled
8
Scale Selection
Displays the selected meter scale: Type I, Type IIa, Type IIb, Type I +
8, Nordic, DIN 45406, dBFS, Zero REF dBFS, Custom dB, and Custom
dBFS
9
Level Markers
Shows peak and reference levels for the signal; this can be adjusted
in the Audio Meter Setup selection options
10
Meter Response
Displays selected meter response: VU, Peak, True Peak, VU + Peak,
VU + True Peak, Custom
11
Audio Graticule (with
meter labels)
Shown as L1, R1, L2, and R2 (or Custom label)
12
Phase Bar (1)
Phase Meter of bar graph 1
13
Phase Bar (2)
Phase Meter of bar graph 2