CMN-91
Installation and Operation Manual
Operation
© 2016 Imagine Communications Corp. Proprietary and Confidential.
Revision D | Page 83
Audio Display
The CMN-91 accepts one AES/EBU and up to four groups of embedded audio inputs. Any two input
channels can be selected to be monitored on the headphone output.
To access the audio display, press and release the AUD function button.
To access Audio Setup menu selection options, press and hold the AUD function button.
Configure the audio display type and parameters using the AUDIO
CHANNEL selection options. Audio
can be displayed as one of the following:
One two-channel bar graph with one Lissajous and one Phase bar
Two two-channel bar graphs (for a total of four channels) with two Lissajous and two Phase bars
Three two-channel bar graphs (for a total of six channels) with three Phase bars or CineSound 5.1
with two Phase bars
Four two-channel bar graphs (for a total of eight channels) with four Phase bars or CineSound
5.1+AUX, 6.1, or 7.1 with up to three phase bars
Eight two-channel bar graphs (for a total of sixteen channels) with eight Phase bars
Lissajous can be selected as Soundstage or X-Y displays.
Input assignments, scaling, input levels, and response can also be modified using the Audio Setup menu
(on page 115).
Audio Scales
The Vertical audio graticule scales change according to the selections made in the AUDIO
METER
SETUP
SCALE selection options. The Scale selection options are as follows:
Type I
DIN 45406
Type IIA
dBFS
Type IIB
Zero Ref dBFS
Type I + 8
Custom dBFS
Nordic
Custom dB