5 Camera Setting and Adjustment
29
UHL-43 2005 VER1 (E)
■ ⑩
FAN CONTROL
Menu Item
Initial
setting
Setting value
Description, Remarks
CAMERA FAN CONT MODE
AUTO
AUTO,
STOP
AUTO
:
Automatically changes the cooling fan speed according to the internal
temperature level.
STOP
:
Keeps the fan stopped as long as the internal temperature does not reach
a critical level. If the power is turned on again, it returns to AUTO.
The surface temperature of the enclosure may be increased higher than the
normal temperature when the STOP mode is selected.
VF FAN
CONT MODE [VF]
AUTO
AUTO,OFF, ON
Sets the FAN operation of VF to AUTO/Force OFF/Force ON.
CAMERA
---
(information display)
SSLOW : The fan speed is very slow.
SLOW
: The fan speed is slow.
NOR
: Normal fan speed.
FAST
: The fan speed is fast.
NG :
Fan
malfunction
VF
---