5 Camera Setting and Adjustment
23
UHL-43 2005 VER1 (E)
■ ⑧
VIDEO ADJUSTMENT
Menu Item
Initial
setting
Setting value
Description, Remarks
AUTO SETUP MODE
―
AUTO SETUP
LEVEL
LEVEL, FULL, QUICK,
F.QUICK, AWS, ABS
Performs the AUTO SETUP process selected.
―
FULL AUTO REF
EXT
INT, EXT
INT : Sets to the default factory setting.
EXT : Sets to the user setting.
―
AWB WITH A.IRIS
ON
ON, OFF
Selects whether to automatically include the A.IRIS when the AWB is performed.
This menu is enabled only during the self contain operation.
It is always “OFF” during the operation with remote controller.
―
AWB DETECT AREA
WIDE
WIDE, SPOT
Selects the DETECT AREA of AWB.
―
AWB MARKER
OFF
ON, OFF
Sets the ON/OFF of the AWB marker display.
―
SMOOTH AWB
ON-0.5s
OFF, ON-0.3s,
ON-0.5s,
ON-0.7s,
ON-1.0s,
ON-1.5s,
ON-2.0s
Sets transition time to change it smoothly between Ach/Bch of AWB.
―
AWB REFERENCE
ON
ON, OFF
ON : Makes the convergence value of the AWB converged to the EXT AWB
REF file.
OFF : Calibrates the Rch/Bch to the Gch.
―
CHART SEARCH
ENABLE
ENABLE, DISABLE
'ENABLE : Automatically adjusts the angle of view of the chart when FULL
AUTO SETUP is performed.
DISABLE
:
Manually adjusts the angle of view of the chart when FULL AUTO
SETUP is performed.
―
REFERENCE SET
ABB
ABB, AWB
Creates the convergence value (EXT REF FILE) of AWB and ABB.