5 Camera Setting and Adjustment
24
UHL-43 2005 VER1 (E)
<< VIDEO ADJUSTMENT continued >>
Menu Item
Initial
setting
Setting value
Description, Remarks
PROCESS SETUP
―
STEP GAIN
0
-6, -3, 0, +3, +6, +9, +12
Sets the step gain.
―
GAIN
―
R
0.0
-100 to +100
Sets the gain value of M/G/R/B.
The gain value decreases in the direction of “-100” and increases in the direction
of “+100”.
―
G
0.0
-100 to +100
―
B
0.0
-100 to +100
―
M
0.0
-100 to +100
―
MANUAL CLR
―
BLK PRS/STR
OFF
-11, -9, -7, -5, -3, +3, +5, +7,
+9, +11, OFF
Sets the level of BLK PRS/STR.
―
GAMMA TYPE
NORMAL
NORMAL, CUSTOM1-5
Selects the type of gamma curve.
NORMAL : Normal gamma curve
CUSTOM1-5 : Custom gamma curve
Refer to the "CUSTOM GAMMA" for custom gamma data editing.
―
STEP GAMMA
0.45
0.45, 0.40, 0.35, OFF
Sets the step gamma.
―
GAMMA
―
R
0.0
-100 to +100
Sets the gamma value of M/R/B.
The gamma value decreases in the direction of “-100” and increases in the
direction of “+100”.
―
B
0.0
-100 to +100
―
M
0.0
-100 to +100
―
MANUAL CLR
―
PED
―
R
0.0
-100 to +100
Sets the pedestal value of M/R/B.
The pedestal value decreases in the direction of “-100” and increases in the
direction of “+100”.
―
B
0.0
-100 to +100
―
M
0.0
-100 to +100
―
MANUAL CLR
―
FLARE
―
R
0.0
-100 to +100
Sets the flare value of G/R/B.
The flare value decreases in the direction of “-100” and increases in the direction
of “+100”.
―
G
0.0
-100 to +100
―
B
0.0
-100 to +100
―
MANUAL CLR
―
DTL
Sets the various Detail correction settings.
―
GAIN
0.0
-100 to +100
Sets the detail amount.
The detail amount decreases in the direction of “-100” and increases in the
direction of “+100”.
―
FREQUENCY
17.0
13.0 to 24.0
Sets the horizontal peak frequency of detail correction.
―
BLACK WHTE
0.0
-100 to +100
Sets the balance between dark area and bright area.
―
BALANCE
0.0
-100 to +100
Sets the balance of the amount between horizontal detail and vertical detail.
―
THRESH
0.0
-100 to +100
Sets the lower limit level to mix the detail correction.
―
FINE
2
0, 1, 2, 3, 4, 5, 6, 7, 8
Reduces the amount of correction for edges with large brightness differences.
―
NOISE SUP
0.0
-100 to +100
Sets the reduction amount of noise.
―
MANUAL CLR
Resets all changes of DTL back to previous setting.
―
HI-LIGHT DTL SETUP
―
HI-LIGHT DTL
OFF
ON, OFF
Enable the high light detail correction.
―
GAIN
-
0to+100
Sets the HI-LIGHT DTL amount.
The detail amount on the high light area increases in the direction of “+100”.
―
LIMIT
-
-100 to +100
Sets the limit level of HI-LIGHT DTL.
―
KNEE
MANUAL
MANUAL, AUTO, OFF
Selects the knee function.
―
SMOOTH KNEE SETUP
―
SMOOTH KNEE
TYPE1
OFF, TYPE1, TYPE2,
TYPE3
Selects the type of SMOOTH KNEE.
―
TEST PULSE
OFF
ON, OFF
Enable the TEST PULSE to adjust SMOOTH KNEE.
―
POINT
75
-100 to +100
Sets the curve of SMOOTH KNEE.
―
SLOPE
10
-100 to +100
―
LOAD INIT
CANCEL
CANCEL, INDIV, ALL
Resets the data of SMOOTH KNEE.
―
MATRIX
1
1, 2, 3, OFF
Select the Matrix mode.
―
ADVANCED MATRIX
OFF
ON, OFF
Turns on/off the advanced matrix.
―
HV SLIM DTL TYPE
H ONLY
H ONLY, V ONLY, H+V
Sets the type of SLIM DTL.
―
V SLIM DTL FREQ
A
A, B, C, D
Sets the boost frequency type of SLIM DTL.
―
NR MODE
OFF
OFF, LOW, HIGH
Sets the NR (noise reducer).
―
DOWN CONV FILTER
STD
STD, HI, HQ, LOW
Setting of FIR-FILTER when the 4K image is converted to HD (1080i & 1080p)