Programming Manual ecomatController/60-1 (CR711S) Operating System V2.5.0.n
2017-12-19
ifm function libraries
Library ifmOutGroup
>
10.6.2
FILTER_OUTPUT_GROUP (ENUM)
23338
Filter setting for voltage measurement in an output group.
The signal of the voltage measurement is damped via a first-order low-pass filter.
Name
Description
Possible values
FILTER_OUTPUT_GROUP
UNCHANGED
No change of settings
FILTER_0
1.7 ms
FILTER_1
1.8 ms
FILTER_2
2.4 ms
FILTER_3
3.9 ms
FILTER_4
7.4 ms
FILTER_5
14.7 ms
FILTER_6
29.3 ms
FILTER_7
58.8 ms
FILTER_8
117.7 ms
FILTER_9
235.6 ms
FILTER_10
471.4 ms
FILTER_11
943.0 ms
FILTER_12
1886.1 ms
10.6.3
MODE_OUTPUT_GROUP (ENUM)
23270
Name
Description
Possible values
MODE_OUTPUT_GROUP Operating type of the output
group
UNCHANGED
Setting remains unchanged
OUT_DIGITAL_CSO
Digital output without
diagnostics and without
protection; CSO
MONITOR
No parameters or process data
are written. Only the FB output
data is updated.
For use in a PLC application to
which the resource does not
belong.
>