System configuration
Configure PLC
>
7.1.2
Allocate inputs/outputs
23482
23368
WARNING
The safety functionality is in preparation.
At present the device has NO safety functionality!
► Do NOT use the device for safety-related functions!
To allocate the I/Os to the PLCs:
Before the programming of the application may even begin:
1 Select I/O allocation
► In the CODESYS device tree: Double-click on symbol [Device (CR711S)]
► In the editor window: Select [I/O Assignment] tab.
>
Editor window shows the PLC allocation of the inputs/outputs (excerpt):
Section
Element
Parameter
Standard
PLC
Safety
PLC
System info
IP Settings
--
Local_IO
Inputs
IN0000
IN0001
IN0002
…
…
…
Outputs
OUT0000
OUT0001
OUT0002
…
…
…
System_Outputs
VBB0_SW
VBB1_SW
…
…
…
Supply_Switch
HMI
User_LEDs
User LED 0
User LED 1
User LED 2
User LED 3
2 Set I/O allocation
► Highlight all I/Os in the column [StandardPLC] to allocate it to the standard PLC
► Highlight all I/Os in the column [SafetyPLC] to allocate it to the safety PLC
>
The I/Os are allocated