ifm function libraries
Library ifmIOcommon.library
>
Diagnostic codes (
→
Messages / diagnostic codes of the function blocks
(
ERR_INVALID_VALUE
Error: at least 1 invalid input parameter or invalid combination of input parameters;
Function call has been stopped.
ERR_INTERNAL
Error: Internal system error
► Contact the ifm Service Center!
ERR_UNDEFINED
Error: Unknown error
► Contact the ifm Service Center!
ERR_SHORT_CIRCUIT
Error: Short circuit with GND or VBBx.
ERR_OPEN_CIRCUIT
Error: Open circuit detected. Possible cause: Wire break.
ERR_OVERLOAD_CURRENT
Error: Maximum current exceeded.
ERR_STUCK_AT
Error: Signal is frozen.
ERR_STUCK_AT_HIGH
Error: Signal frozen, signal state high.
ERR_STUCK_AT_LOW
Error: Signal frozen, signal state low.
ERR_OVERVOLTAGE
Error: Maximum signal voltage exceeded.
ERR_UNDERVOLTAGE
Error: Minimum signal voltage not reached.
ERR_UNDERVOLTAGE_VBBX
For inputs: Error: Reference voltage not reached.
For outputs. Error: The voltage of the corresponding output group supply or at
VBB30 / VBB15 is not reached.
ERR_OVERVOLTAGE_VBBX
For inputs: Error: Reference voltage exceeded.
For outputs. Error: Voltage of the corresponding output groups supply or at VBB30
/ VBB15 not reached.
DIAG_INVALID_VALUE
At least one input parameter is invalid or exceeds the permissible area.
DIAG_INTERNAL
Internal system error.
DIAG_OPEN_CIRCUIT
Open circuit detected. Possible cause: Wire break.
DIAG_SHORT_CIRCUIT
Error: Short circuit with GND or VBBx.
DIAG_UNDERVOLTAGE_VBBX
For inputs: Error: Reference voltage not reached.
For outputs. Error: The voltage of the corresponding output group supply or at
VBB30 / VBB15 is not reached.
DIAG_OVERVOLTAGE_VBBX
For inputs: Error: Reference voltage exceeded.
For outputs. Error: Voltage of the corresponding output groups supply or at VBB30
/ VBB15 not reached.
DIAG_OVERLOAD_CURRENT
Maximum current exceeded.
DIAG_STUCK_AT
Error: Signal is frozen.
DIAG_STUCK_AT_HIGH
Error: Signal frozen, signal state high.
DIAG_STUCK_AT_LOW
Error: Signal frozen, signal state low.
DIAG_OVERVOLTAGE
Maximum signal voltage exceeded.
DIAG_UNDERVOLTAGE
Error: Minimum signal voltage not reached.
DIAG_NO_CALIB
The selected resource has no valid calibration.
The displayed values are maybe faulty.
DIAG_ACCESS
FB/Function cannot access the required resource; Resource is blocked by another task.
DIAG_CHANGEOVER_TIME
Minimum changeover time for the highside-lowside selection of the drivers has not yet
expired.
>