141
ifm
Programming Manual ecomatController/60-1 (CR711S) Operating System V2.5.0.n
2017-12-19
ifm function libraries
Library ifmIOcommon.library
>
10.5.10
MODE_OUTPUT (ENUM)
23169
Name
Description
Possible values
MODE_OUTPUT
Operating mode of the
outputs
UNCHANGED
Preset mode is maintained
OUT_DIGITAL_CSI
Digital output without diagnostics; CSI
OUT_DIGITAL_CSO
Digital output without diagnostics;
CSO
OUT_ANALOGUE_10
Analogue output to generate a
selectable voltage 0...10 V without
diagnostics. Generated with the help
of a filtered PWM signal. CSO
OUT_SENSOR_05
Output with fixed output voltage 5 V
for the sensor supply without
diagnostics and without protection.
CSO
OUT_SENSOR_10
Output with fixed output voltage 10 V
for the sensor supply without
diagnostics and without protection.
CSO
MONITOR
No parameters or process data are
written. Only the FB output data is
updated.
For use in a PLC application to which
the resource does not belong.
10.5.11
SYS_VOLTAGE_CHANNEL (ENUM)
23170
Name
Description
Possible values
SYS_VOLTAGE_CHANNEL List of all available system voltages. VBB30
Terminal 30 system voltage
VBB15
Terminal 15 system voltage of the
ignition switch
>