Programming Manual ecomatController/60-1 (CR711S) Operating System V2.5.0.n
2017-12-19
ifm function libraries
Library ifmOutPWM
>
10.8.3
MODE_CURRENT_CONTROL (ENUM)
23361
Name
Description
Possible values
MODE_CURRENT_CONTROL Operating mode of the
output
UNCHANGED
Setting is maintained
OUT_CURRENT_CSO
Output for current control
without diagnostics and
without protection; CSO
OUT_CURRENT_CSO_DIAG
Output for current control
with diagnostics and
without protection; CSO
OUT_CURRENT_CSO_DIAG_PROT Output for current control
with diagnostics and
protection; CSO
MONITOR
No parameters or
process data are written.
Only the FB output data
is updated.
For use in a PLC
application to which the
resource does not
belong.
10.8.4
MODE_PWM (ENUM)
23348
Name
Description
Possible values
MODE_PWM
Operating mode of the output
UNCHANGED
Setting is maintained
OUT_PWM_CSI
PWM output without diagnostics;
CSI
OUT_PWM_CSO
PWM output without diagnostics;
CSO
OUT_PWM_CSO_DIAG
PWM output with diagnostics and
without protection; CSO
OUT_PWM_CSO_DIAG_PROT
PWM output with diagnostics and
with protection; CSO
MONITOR
No parameters or process data
are written. Only the FB output
data is updated.
For use in a PLC application to
which the resource does not
belong.