91
ifm
Programming Manual ecomatController/60-1 (CR711S) Operating System V2.5.0.n
2017-12-19
Operation
Transfer CODESYS project to device
9
Operation
Transfer CODESYS project to device ................................................................................................. 91
Operating states .................................................................................................................................. 93
Status LEDs ......................................................................................................................................... 94
Reset ................................................................................................................................................... 97
Data transmission for series production .............................................................................................. 99
Display system information ............................................................................................................... 101
23280
► Familiarise yourself with the following CODESYS functions!
Translate project/application and transfer to the device
→ Online help > CODESYS Development System > Transferring Applications to the PLC
9.1
Transfer CODESYS project to device
Load the application to the device ....................................................................................................... 91
Delete application from CR711S ......................................................................................................... 92
23493
To save the CODESYS project on the device, transfer the following component:
Application (
→
Load the application to the device
(
► Observe notes on the operating modes of the PLC of the device!
→
Operating states of CR711S
>
9.1.1
Load the application to the device
23494
To transfer the created application as boot project to the device:
Requirements:
>
Communication path is set (→
Set communication path of PLC
(→ p.
>
Project tested.
1 Translate application
►
In the device tree: highlight application as active application.
►
Use [Build] > [Rebuild] to translate the active application.
>
CODESYS generates program code.
2 Load application to the device
►
Only for safety PLC: Change to debug mode with [SIL2] > [Enter debug mode…].
►
Use [Online] > [Login] connect with the device.
>
Active application is loaded to the device (download).
>
Application on the device is in the STOP state.
3 Start application
►
Use [Debug] > [Start] to start the application.
>
Application goes to the RUN state.