75
ifm
Programming Manual ecomatController/60-1 (CR711S) Operating System V2.5.0.n
2017-12-19
System configuration
Configure interfaces
>
Attach J1939-ECU
► In the CODESYS device tree: Right mouse click on [Communication] > [CAN] > [ifmCANBus] >
[J1939_Manager].
► Select [Add Device...].
>
Window [Add Device] appears.
► In the area [Device]: [Vendor:] select <All vendors>.
► In the list below: Select [Fieldbusses] > [J1939] > [J1939_ECU] > [J1939_ECU].
► Confirm the selection with [Add Device].
► Close the window [Add Device] with the [Close] button.
Set J1939-ECU parameters
► In the CODESYS device tree: Double-click on [Communication] > [CAN] > [J1939_Manager] >
[J1939_ECU].
► Make the following settings in the tab [General] in the section [General] according to the specific
application:
user case
[Local Device]
Significance [Preffered Address]
Receiving broadcast data of the ECU
No transmission
deactivated
Address of the ECU from which the data is to be
received
Sending data (broadcast and P2P)
Receiving P2P data
activated
Address of the ifm controller
► Add parameter groups in the tab [TX-Signals] by clicking on [Add PG].
>
The settings become valid with menu [File] > [Save Project].
>
via function block: RAW-CAN
23160
The
Library ifmRawCAN.library
(
) features several function blocks for this application.