40
ifm
Programming Manual ecomatController/60-1 (CR711S) Operating System V2.5.0.n
2017-12-19
System description
Hardware description
>
Input type IN RESISTOR-A
23083
Binary inputs and resistance measurement
Block diagram
IN RESISTOR-A
IN#### =
Connection of frequency / counting input
no. ####
(CR) = device
(1) = input filter
(2) = CSI binary input
plus-switching
(3) = measured value (analogue)
Configure input
→ Chapter System configuration
Possible operating modes:
Binary input CSI (B
L
) (R
E
= 10 k
) or Namur
Resistance measurement 0...30 k
>
Input type IN DIGITAL-A
23087
Binary inputs
Block diagram
IN DIGITAL-A
IN#### = Connection of binary input no.
####
(CR) = device
(1) = input filter
(2) = measured value (analogue)
Input not configurable
Possible operating modes:
Binary input CSI (B
L
) (R
E
= 10 k
) or Namur