D. SPECIFIC START-UP PROCEDURE
"
"
Make the accessories' electrical connections.
"
"
Start up the boiler only.
"
"
Make the following settings:
On boiler No. 1: master
Line No. Value
• Configuration
menu
Boiler pump supplied by IDEAL
No adjustments necessary
Boiler pump supplied by the customer (all-or-
nothing control)
Relay output QX3
(5892) Boiler pump Q1
Diagram : VF10
page 3 / 7
Boiler No. 2 (and the following ones):
L2
N
L3
N
L3
L1
N
QX2
QX3
QX1
}
L
N
PWM
GND
Boiler pump, if
supplied by IDEAL
}
}
230 V
AC 50 Hz
power supply
Alarm relay
Boiler pump, if supplied by customer
DB MB
}
LPB Bus
UX2
Gnd
UX3
Gnd
If a command pump (boiler, heating and/or DHW circuit)
is connected, refer to § 9.4 for the specific configuration)