122 / 136
00RNO0333-B (U0625869)
EVO S -
Installation and Servicing
Line
No.
Programming
Access
Default value
Customer setting
1680
Optg mode changeover
S
Off
Consumer circuit 1
1859
Flow temp setp cons request
C
60 °C
1875
Excess heat draw
S
On
1878
With buffer
S
No
1880
With prim contr/system pump
S
No
Consumer circuit 2
1909
Flow temp setp cons request
C
60 °C
1925
Excess heat draw
S
On
1928
With buffer
S
No
1930
With prim contr/system pump
S
No
Consumer circuit 3
1959
Flow temp setp cons request
C
70 °C
1975
Excess heat draw
S
On
1978
With buffer
S
No
1980
With prim contr/system pump
S
No
Swimming pool
2055
Setpoint solar heating
S
26 °C
2056
Setpoint source heating
S
22 °C
2065
Charging priority solar
S
Priority 3
2080
With solar integration
S
Yes
Boiler
2203
Release below outside temp
S
--- °C
2208
Full charging buffer
S
Off
2210
Setpoint min
S
8 °C
2212
Setpoint max
S
80 °C
2214
Setpoint manual control
E
60 °C
2217
Setpoint frost protection
S
7 °C
2243
Burner off time min
S
5 min
2245
SD burner off time
S
10 °C
2250
Pump overrun time
S
5 min
2253
Pump overr time after DHW
S
1 min
2270
Return setpoint min
S
8 °C
2321
Starting speed
S
S 50:
S 70:
S 95:
S 115:
S 135:
72 %
57 %
80 %
79 %
63 %
2322
Pump speed min
S
S 50:
S 70:
S 95:
S 115:
S 135:
72 %
57 %
80 %
79 %
63 %
2323
Pump speed max
S
S 50:
S 70:
S 95:
S 115:
S 135:
72 %
57 %
80 %
79 %
63 %
2330
Output nominal
S
S 50:
S 70:
S 95:
S 115:
S 135:
60
70
100
120
134
Содержание EVO S 50