Subject to technical changes | Valid from July 2021
Subject to technical changes | Valid from July 2021
33
REFRIGERATED DISPLAY CASES
2.4.2. INSTALLATION OF THE UNIT ABOVE 2000 M ABOVE SEA LEVEL
To install the unit you require:
• At least two persons
•
Tools:
- adjustable wrench or pipe wrench (for units with a pedestal)
- spirit level
- possibly a special tool for the refrigeration unit
Preparation
The installation personnel are responsible for the stability or support of the unit. Ensure that the appliance cladding and counters are
prepared in accordance with the technical specifications. The size of the installation opening can be found in the current product
catalogue under “Technical data” of the respective product group, on the manufacturer’s website or in the order specification. Protect
the surfaces of the unit and the base against any damage during the installation.
All work, installations, deliveries and services may only be carried out by authorised refrigeration companies and qualified specialists.
Electrical installations may only be carried out by an authorised specialist. You must ensure that suitable personnel and tools are
available to prevent damage and injuries.
The unit is intended for use up to 2000 m above sea level.
When used above 1500 m above sea level, pressure relief must be provided for insulating glass to prevent damage to the glass. All
insulating glass display cases are delivered WITHOUT pressure relief as standard. Contact your service partner or the manufacturer
for more information.
The base must be placed level to enable the condensate to drain off. Test whether the water on the inside of the well
can also drain out.
The manufacturer is not liable for any damage caused to the unit or components (e.g. glass breakage, etc.) in the event
of incorrect installation or additional modifications required (e.g. pressure relief) for specific environmental parameters
of the unit.
NOTE
NOTE
Содержание AKV 116
Страница 1: ...Betriebsanleitung KÜHLVITRINEN Original 21A ...
Страница 2: ...Technische Änderungen vorbehalten Gültig ab Juli 2021 2 ...
Страница 25: ...Technische Änderungen vorbehalten Gültig ab Juli 2021 25 NOTIZEN ...
Страница 39: ...Technische Änderungen vorbehalten Gültig ab Juli 2021 39 NOTIZEN ...
Страница 57: ...Technische Änderungen vorbehalten Gültig ab Juli 2021 57 NOTIZEN ...
Страница 81: ...Technische Änderungen vorbehalten Gültig ab Juli 2021 81 NOTIZEN ...
Страница 83: ......
Страница 85: ...Operating Manual REFRIGERATED DISPLAY CASES Translation of the original 21A ...
Страница 86: ...Subject to technical changes Valid from July 2021 2 ...
Страница 109: ...Subject to technical changes Valid from July 2021 25 NOTES ...
Страница 123: ...Subject to technical changes Valid from July 2021 39 NOTES ...
Страница 141: ...Subject to technical changes Valid from July 2021 57 NOTES ...
Страница 165: ...Subject to technical changes Valid from July 2021 81 NOTES ...
Страница 167: ......