Subject to technical changes | Valid from July 2021
20
GENERAL INFORMATION AND SAFETY
REFRIGERATED DISPLAY CASES
01
1.14.
RESIDUAL DANGERS
Even with maximum care being taken during the design and construction of the units, and safety-relevant circumstances being
taken into account, there can still be residual dangers that were evaluated by means of a risk assessment. This chapter lists all the
residual risks and safety instructions from the risk assessment.
Ignition danger from electric sparks or sparks caused by friction, and from hot surfaces
With refrigerant R290, an explosive gas/air mix can be created as a consequence of possible leaks in the refrigeration sys
-
tem. The sparks from a vacuum cleaner or other electrical device may unintentionally ignite this mixture. No hot surfaces
may be present or produced. For cleaning, maintenance and service work only use devices that comply with the applicab
-
le ATEX Directive.
WARNING
Danger of crushing when inserting or repositioning the units in the counter opening/cut-out
When inserting units, be aware of the danger of crushing, including for third parties. Manual lifting of the units must be
carried out by at least four persons. These persons must be strong enough to be able to carry the units. Pushing or mo
-
ving the units is not permitted. Call in another person for spotting if necessary. Wear protective gloves and safety shoes for
installation and loading work.
WARNING
Danger of crushing and danger from falling objects when handling/aligning/positioning heavy individual components
When handling heavy objects, be aware of possible crushing dangers, including for third parties. If possible, use both
hands when handling heavy objects. Get another person to help you if necessary. When handling/aligning/positioning
heavy individual components, protective gloves and safety shoes must be worn.
WARNING
Danger of colliding with the units during installation, cleaning and maintenance work
Be aware of possible dangers of colliding with the unit.
WARNING
Danger of crushing/cutting when handling the evaporator box
When lifting and reinserting the evaporator box, use the metal rod provided for this. When lifting the evaporator box,
Ensure that it is lifted until the locking tabs snap into place automatically. Hold the evaporator box firmly on the metal rod
or in position before unlocking.
WARNING
Danger from leaking refrigerant from a damaged evaporator
No sharp objects may be used for cleaning the evaporator fins. The evaporator fins may only be cleaned using products
specified by the manufacturer.
WARNING
Содержание AKV 116
Страница 1: ...Betriebsanleitung KÜHLVITRINEN Original 21A ...
Страница 2: ...Technische Änderungen vorbehalten Gültig ab Juli 2021 2 ...
Страница 25: ...Technische Änderungen vorbehalten Gültig ab Juli 2021 25 NOTIZEN ...
Страница 39: ...Technische Änderungen vorbehalten Gültig ab Juli 2021 39 NOTIZEN ...
Страница 57: ...Technische Änderungen vorbehalten Gültig ab Juli 2021 57 NOTIZEN ...
Страница 81: ...Technische Änderungen vorbehalten Gültig ab Juli 2021 81 NOTIZEN ...
Страница 83: ......
Страница 85: ...Operating Manual REFRIGERATED DISPLAY CASES Translation of the original 21A ...
Страница 86: ...Subject to technical changes Valid from July 2021 2 ...
Страница 109: ...Subject to technical changes Valid from July 2021 25 NOTES ...
Страница 123: ...Subject to technical changes Valid from July 2021 39 NOTES ...
Страница 141: ...Subject to technical changes Valid from July 2021 57 NOTES ...
Страница 165: ...Subject to technical changes Valid from July 2021 81 NOTES ...
Страница 167: ......