10
MENU SCREEN OPERATION
10-56
Function items (Continued)
■
VOX Time-Out Timer
(Default: 3min)
Function > VOX > VOX Time-Out Timer(VOX TIME-OUT TIMER)
Set the VOX Time-Out Timer to 1, 2, 3, 4, 5, 10 or 15 minutes to prevent an
accidental prolonged transmission.
To disable the function, set it to “OFF.”
• OFF
: Turns the function OFF.
• 1, 2, 3, 4, 5, 10 or 15 min : If a continuous transmission exceeds the set
period, the transmission will be cut off.
Headset Select
(Default: Other)
Function > VOX > Headset Select(HEADSET SELECT)
Select the headset type to be connected.
• HS-95 : Select when the HS-95 is connected.
• Other : Select when the HS-94 or HS-97 is connected.
CI-V Address
(Default: 84)
Function > CI-V > CI-V Address(CI-V ADDRESS)
To distinguish equipment, each CI-V transceiver has its own Icom standard
address in hexadecimal code.
The ID-31A/E’s default address is 84.
When 2 or more ID-31A/Es are controlled through a PC at the same time,
set a different address for each device between 01h and DFh (hexadeci-
mal).
CI-V Baud Rate
(Default: Auto)
Function > CI-V > CI-V Baud Rate(CI-V BAUD RATE)
Set the CI-V data transfer speed to 300, 1200, 4800, 9600, 19200 bps or
Auto.
When “Auto” is selected, the baud rate is automatically set according to the
data rate of the controller.
CI-V Transceive
(Default: OFF)
Function > CI-V > CI-V Transceive(CI-V TRANSCEIVE)
Turn the CI-V Transceive function ON or OFF.
• OFF : Turns the function OFF.
• ON : When you change a setting on the transceiver, the same change
is automatically set on other connected transceivers or receivers,
and vice versa.
Previous view