background image

®

K5437R 

1 GANG LEADED MULTI-FUNCTION SWITCH 
RECEIVER 

Installation & Operating Instructions 

Various electric loads such as lamp bulbs, HV halogen lamps, electronic 
ballast devices and inductive loads can be switched with output 1

v

 of the 

receiver.  The receiver is operated with Echo transmitters (radio signal).  
Before use, the transmitters must be assigned to the receiver (max. 32 
receivers).  Every transmitter can control an unlimited number of 
receivers.

 

SAFETY: 

CAUTION!  230V, Danger of electrical shock!

    Always 

disconnect the electricity supply before commencing work on 
the installation. 

The device should be installed by a competent person or a qualified 
electrician in accordance with the device’s installation instructions and 
the appropriate current national wiring regulations. 
It is essential that all connections are made as instructed, that cables are 
not stressed and that terminals are fully tightened. 
Screwless terminals must not have more than one cable inserted into 
each terminal. 
The mains supply to this product must be protected by an appropriate 
fuse or MCB. 

SPECIFICATION: 

 

General Data

 

Transmit frequency

 

868.3MHz 

Power supply

 

230V~ / 50Hz 

Power line protection

 

Circuit breaker rated for 16A max 

Ambient temperature

 

-20 to +40°C 

Storage temperature

 

-40 to +85°C 

Test specifications

 

EN 60669-2-1 

Identification

 

CE; KEMA/KEUR 

Protection type

 

IP20 

Load Types

 

Incandescent lamps 

2500W 

HV halogen lamps 

1200W 

Inductive 

600VA 

Electronic transformer 

3 units 

INSTALLATION: 

General Information

 

• NEVER install Echo receivers in a metal enclosure or in the 

immediate vicinity of large metal objects. 

•  Installation close to floor level or on the floor is not recommended. 

Installation

 

Important:

  This device should be installed into a flush mounted 

installation box. 
The receiver’s housing design also makes it ideally suitable for 
installation in a false ceiling.  This is accomplished by using the 
mounting hole in the middle of the housing. 

Caution!  

All Echo transmitters to be used should be assigned and 

programmed with the desired function prior to final installation of this 
receiver in a false ceiling. 
 
 

 

•  Install receiver in a suitable position. 
•  Protect power supply line with an automatic circuit breaker (max 16A) 
•  Install connection cables. 

Commissioning

 

•  Switch on power supply after installation. 

• 

Program the receiver

 

RF RANGE: 

The strength of the radio signal between the transmitter and switching 
receiver weakens as distance increases.  The range can be further 
reduced by different materials or interference sources in the propagation 
direction of the radio waves.  The range can be increased by the use of 
Echo Repeaters (radio amplifiers). 

Material

 

Reduction

 

Wood, plaster, non-coated glass 

0 - 10% 

Masonry, wood/plaster walls 

5 - 35% 

Reinforced concrete 

10 - 90% 

 

Range

 

Conditions

 

> 30 m 

Under good conditions (large, clear space without 
obstructions). 

> 20 m 

Through up to 5 plaster/drywall board walls or 2 
brick/porous concrete walls (furniture and persons in 
the room): 
For transmitter and receiver with good aerial 
positioning/layout. 

> 10 m 

Through up to 5 plaster/drywall board walls or 2 
brick/porous concrete walls (furniture and persons in 
the room): 
For receivers installed in walls or corners of rooms, 
receivers with internal aerial or narrow corridors. 

Through 1-2 

ceilings / walls

Depending on ceiling/wall armouring and type of 
aerial in the receiver. 

PROGRAMMING: 

For programming, the receivers must be connected to the mains power 
supply.  The programming is retained even in a power failure. 

Learn Mode:  Assigning and Deleting Transmitters

 

 