10
MENU SCREEN OPERATION
10-48
DV Set items (Continued)
■
BK
(Default: OFF)
DV Set > BK(BK)
The BK (Break-in) function allows you to break into a conversation, where
the two other stations are communicating with call sign squelch enabled.
• OFF : Turns the function OFF.
• ON : Turns the function ON.
“BK” appears on the display.
NOTE:
The BK function is automatically turned OFF when transceiver is
turned OFF.
EMR
(Default: OFF)
DV Set > EMR(EMR)
The EMR communication mode can be used in the digital mode. In the
EMR mode, no call sign setting is necessary.
When an EMR mode signal is received, the audio (voice) will be heard at
the specified level even if the volume setting level is set to minimum level,
or digital call sign/digital code squelch is in use.
• OFF : Turns the function OFF.
• ON : Turns the function ON.
“EMR ” appears on the display.
NOTE:
The EMR function is automatically turned OFF when transceiver
is turned OFF.
EMR AF Level
(Default: 19)
DV Set > EMR AF Level(EMR AF LEVEL)
Set the audio output level to between 0 and 39 for when an EMR commu-
nication mode signal is received.
When an EMR signal is received, the audio will be heard at the set level, or
the [VOL] control level, whichever is higher.
To disable the setting, set it to “0.”