Sonde Introduction

Sondes are small self-contained battery powered transmitters that are propelled through pipes 
and ducts and can be located on the surface by a sonde locator or buried utility locator with a 
sonde mode. Sondes are also built into other products such as a sewer camera, robotic crawler 
camera, or attached to a jetter hose. Low-frequency versions (512Hz/640Hz) can transmit 
through some metallic pipes like cast iron pipes, which is why they are frequently used with sewer 
inspection cameras.

Sondes come in a variety of sizes which ties into how deep they can be located. Different frequen-
cies are available which allow sondes to be located in metallic or non-metallic pipes and ducts.

The vScan receiver has sonde frequencies of 33kHz, 512Hz and 640Hz.

P/N:4.04.000223

Page 1

Sonde Range

Model

Depth and Dimensions

Frequency

Battery Type

D18 Sonde

D38 Sonde

D64 Sonde

D23 Sonde

Please visit our website for full specifications on our sonde range.

Depth:

 15ft / 4.5m

0.72" x 3.2" (18.5 x 79mm)

33kHz

33kHz

33kHz

Depth:

 16ft / 5m

1.4" x 5.2" (38 x 132mm)

Depth:

 26ft / 8m

2.5” x 7.1” (64 x 179mm)

Depth:

 22ft / 7m

0.90" x 17.3" (23 x 440mm)

512Hz

640Hz

2 x SR44

Button cells

1 x AA Alkaline

1 x 9 Volt Alkaline

1 x AA Alkaline

Содержание vScan D18

Страница 1: ... inspection cameras Sondes come in a variety of sizes which ties into how deep they can be located Different frequen cies are available which allow sondes to be located in metallic or non metallic pipes and ducts The vScan receiver has sonde frequencies of 33kHz 512Hz and 640Hz P N 4 04 000223 Page 1 Sonde Range Model Depth and Dimensions Frequency Battery Type D18 Sonde D38 Sonde D64 Sonde D23 So...

Страница 2: ...he camera or duct rodder When working with sondes always use a fresh battery Use a radio system or mobile phone for communication Work in increments of 10 to 20 feet 3 to 6m Locate mark move and repeat TIP MAIN PEAK GHOST PEAK GHOST PEAK 1 2 3 Turn on the vScan Receiver Use the mode paddle to enter the Sonde mode The Sonde icon will now be visible on the screen Position the vScan above the Sonde a...

Страница 3: ... 75 Now move the vScan forward and back to detect the largest signal You will also notice that there will be a ghost signal in front and behind the Sonde This is normal and characteristic of locating Sondes Ghost Peak Ghost Peak Main Peak Forward Back Locate Left Right position Locate ...

Страница 4: ...peat the above to mark the pipe or duct route Keep the insertion intervals small 2 to 3m to ensure the Sonde is not lost Vivax Metrotech Corp Headquarters 3251 Olcott Street Santa Clara CA 95054 USA T Free 1 800 446 3392 Tel 1 408 734 1400 Fax 1 408 734 1415 Email SalesUSA vxmt com Website www vivax metrotech com Visit us at www vivax metrotech com to view our full product line and worldwide locat...

Отзывы: